9.3.5 Input process interface (device dependant)

Via the input process interface it is possible to set, for example, the expected values of the identification
(barcode, matrixcode, text) sensors using the SP ("Set Parameter") command. You can also set parameters
for image acquisition.
The length of the datagram includes the header and end identifier.
You may select as many entries for the transfer as you wish in the table.
+
With the
and
buttons, you may add a new line or erase the currently selected line, respectively. Each
line contains one feature to be transferred. Using the arrow keys, the currently selected line can be moved
upward or downward thereby changing the data sequence in the data packet.
General settings
Parameters
Start
Separator
End
NOTE
To enter binary characters, you may use the \ symbol in the text. The value can then be
specified in hexadecimal format. To add a backslash, enter \ \ . The character \00 cannot
be used.
Example:
\\09
\0D\0A
v2.11.0-B4
Meaning
Character string as a start sequence preceding the data block. This
character string is freely selectable (e.g. <Start>).
Character string included as a delimiter between each individual result of the
feature check (e.g.)
Character string as an end sequence concluding the data block. This
character string is freely selectable (e.g. <End>).
correspondents to a tab
corresponds to <CR><LF>