10.4 Digital I/O Assistant
With the Digital I/Os assistant, you can test whether all cables are connected correctly to the digital inputs
and outputs. To use the illumination controller, the device must be in Configuration mode.
If the menu option is still greyed, your device may have the wrong firmware version.
ATTENTION!
If your Vision Sensor has already been permanently integrated into your system, it is
advisable during initial testing to check the outputs with a meter. Keep in mind that
switching of the outputs will be transmitted to any connected controllers!
NOTE
If encoders are defined for the inputs 4 and 5, you cannot test these using this assistant!
You can change the settings under:
Device → Device settings → Digital I/Os.