15.4.11 GS command – request thermal condition
This function enables you to query the device's current thermal state. The internal temperature sensor is
queried for this and the capacity is output in %.
An internal protection device intervenes when the device is operated outside of specification; this is intended
to protect the components against destruction by heat. The device will undergo emergency shutdown when
100% capacity is reached.
The Application Suite, the web-interface and the process interfaces will output an overheating warning to
notify users that the maximum permissible operating temperature (circa 85–90% of loading) has been
reached (see GA temperature alarm command).
Example
Structure of the command PLC
Command
Parameters
G
T
Get
none
Thermal
Condition
Structure of the Response PLC
Response
R
T
0
0
Response
8 byte ASCII hex
Thermal
Thermal state
Condition
Parameters of the "RS" command – current thermal state
The percentage value for capacity of the temperature range before emergency thermal shutdown (100%
capacity) is transmitted using 8 characters, the first 6 characters in a bit mask are always 0 and the current
thermal state is contained in ASCII characters 7 and 8.
Bits
3
2
1. ASCII characters
3. ASCII characters
5. ASCII characters
7. ASCII characters
v2.11.0-B4
device
device
0
0
0
0
0
0
1
0
0
0
0
Thermal state
3
2
2. ASCII characters
4. ASCII characters
6. ASCII characters
8. ASCII characters
319/429
Technical Documentation
VeriSens
1
0
0
0
0
Baumer Optronic GmbH
Radeberg, Germany
®

Advertisement

Table of Contents
loading

Table of Contents