15.4.10 GS command – request status
This function enables you to access current status information for the device.
Example
Structure of the command PLC
Command
Parameters
G
S
Get State
none
Structure of the Response PLC
Response
R
S
0
Response
4 byte ASCII hex
State
Status
NOTE
A TCP/IP connection can be monitored, for example by the PLC cyclically sending the GS
command. If the connection is broken, this is shown on the Vision Sensor page and the
connection is reset.
Parameters of the "RS" command – Current status information
The current status information consists of 8 characters, of which the first 4 characters describe various states
in a bit mask and the other 4 characters contain the current job number.
v2.11.0-B4
device
device
0
8
5
4 byte ASCII hex
Number of the active job
0
0
1
A