Receipt Timeout - Baumer VeriSens ID Series Technical Documentation Manual

Vision sensor
Hide thumbs Also See for VeriSens ID Series:
Table of Contents

Advertisement

15.3.4 Receipt timeout

Signal
Receive timeout T
1
If errors occur in the communication, receiving is terminated after a defined time. The data received to this
point is then discarded. The possible error causes may be:
The cable was unplugged or mechanically damaged during the transfer.
Transmission of the data was prematurely terminated due to a technical fault.
An error occurred in the transfer of the length information, so that the information is incorrectly
transferred. The device then presumes an incorrect overall length of the data.
v2.11.0-B4
Duration
min.
10 ms
304/429
Technical Documentation
max.
2000 ms
Baumer Optronic GmbH
Radeberg, Germany
®
VeriSens

Advertisement

Table of Contents
loading

Table of Contents