Baumer VeriSens ID Series Technical Documentation Manual page 47

Vision sensor
Hide thumbs Also See for VeriSens ID Series:
Table of Contents

Advertisement

(device dependant)
Click on Generating automatic suggestion... to view a suggestion for illumination settings.
Enter the speed of the objects, and their distance from the camera, during inspection. The Application Suite
automatically calculates the associated parameters. If the image is then still too dark or bright, you can adjust
this using the control gain (Amplification).
(device dependant)
NOTE
Depending on the form of construction, devices with CMOS sensors may experience
brightness deviations during the first images taken after a longer break in image exposure
and the associated variations in temperature.
This is not an issue in Run mode (Continuous), since images are taken continuously.
In Trigger mode (External trigger), however, the device only records an image after a
trigger event.
Longer breaks between triggers should be avoided to prevent brightness deviations.
Continuous: A new image acquisition is made as soon as an image analysis is complete. You can also limit
the number of images depending on the exposure time.
External trigger: A new image is acquired upon the occurrence of a corresponding external event.
If an encoder is connected, you can also specify the delay time or distance (ft = feet) between the trigger
signal and the actual image acquisition. Any other trigger signals received during this period are ignored!
If necessary, activate the "invalid trigger" entry (trigger during image acquisition or job switching) in Device
settings, so that the alarm output is activated in such cases.