Initial Set-Up Of The Ethernet Interface On Your Computer - Baumer VeriSens ID Series Technical Documentation Manual

Vision sensor
Hide thumbs Also See for VeriSens ID Series:
Table of Contents

Advertisement

6.7 Initial set-up of the Ethernet interface on your computer

1. Assigning an IP address
To use the device in your network, you must assign a unique IP address to the device. Below is the default
factory configuration:
1. If you have a DHCP server integrated into your network, the IP address is requested from this
server. No additional manual actions are necessary on your part.
2. If a valid IP address cannot be obtained within 15 seconds, the default IP address of
192.168.0.250 (subnet mask: 255.255.255.0) is used.
NOTE
To avoid network malfunctions, ensure that each IP address is unique within your network
and has not already been assigned!
Now, link your PC into the same network as the device. Under certain circumstances, you may need to
configure the IP address of your PC for this purpose. With Microsoft
1. Open: Start menu → System controller → Network and Internet (display network status and tasks) →
Amend adapter settings
2. Select your network (e.g., "Local Area Connection") and then the "Properties" entry in the context
menu.
3. Select the "Internet protocol version 4 (TCP/IPv4)" entry in the list of elements and then click the
Properties button below the selection list. The following dialogue box opens:
Activate the Use the following IP address option and select an address in the range
192.168.0.xxx that has not yet been used for the IP address. Enter 255.255.255.0 for the
subnet mask and confirm these settings.
v2.11.0-B4
®
Windows
28/429
Technical Documentation
VeriSens
®
7, proceed as follows:
Baumer Optronic GmbH
Radeberg, Germany
®