Group: Parameters - Baumer VeriSens ID Series Technical Documentation Manual

Vision sensor
Hide thumbs Also See for VeriSens ID Series:
Table of Contents

Advertisement

15.5.3.4 Group: Parameters

This group is used to transfer parameter data for the current job. It is configured during job creation in the
Application Suite in the step Configure interfaces → Input process interface.
Depending on the protocol versions are available with payload capacities of 4/8/16/32/64/128/250 bytes. You
should choose the smallest possible version for the volume of data you expect to handle. An unnecessarily
large selection reduces overall system performance.
The data corresponds with the "SP" command in the classic process interface.
Data element
Direction
PLC
Actual length of
the parameters
PLC
Parameter (<n>
byte)
v2.11.0-B4
Type
Length
(byte)
device
UINT16
2
device
OCTET-
4/8/16/3
STRING
2/64/128
/250
Description
Length of data actually used in ParamData
Parameter data for the current job
344/429
Technical Documentation
VeriSens
Baumer Optronic GmbH
Radeberg, Germany
®

Advertisement

Table of Contents
loading