9.3.3 Output Robotics (device dependent)

In this dialogue, you can configure the data outputs for the Robotics.
NOTE
You can configure the activation of this interface in the Device settings.
Device  Device settings  Robotics
Waypoint feature: Select the feature check for the waypoints of the robot. The first robot-compatible feature
check that has been configured is entered automatically. If no robot-compatible feature check is selected,
then no waypoint coordinates determined by the image processing can be used.
NOTE
To be able to select a feature check on Feature by Waypoint, the distortion correction and
Z calibration must be configured. Furthermore, Convert image coordinates to world
coordinates must be activated.
+
With the
and
buttons, you may add a new line or erase the currently selected line, respectively. Each
line contains one feature to be transferred.
v2.11.0-B4