Data table settings
The following items are selected in the table:
Column
Meaning
Active
If this entry is marked, the selected value for the robot control is entered in the datagram.
Feature
The setting or the feature check from which a value is to be transferred is selected here.
Value
The result of the feature check that is to be transferred is selected here. The "Result" option
(for the OK/NOK result of the feature check) is always available. All other results depend on
the relevant feature check or setting.
Variable
Here you can specify a variable name. This is freely selectable, but is automatically prefixed
VSV_. You can add 11 additional characters.
name
If nothing is entered, it is automatically numbered ( VSV_Var1, VSV_Var2,
VSV_Var...)
These variables are then available in the robot controller.
The following table explains the meaning of various settings for features and values.
Parameters
Feature
Value
Time
Image acquisition Provides the time of the image acquisition in milliseconds since the
Result
Total result
Result
Partial result
Statistics
Total result
Statistics
Partial result
Trigger
Additional data
trigger
Trigger
Image counter
NOTE
Following the descriptions of the individual feature checks, there is a table containing the
values which can be output via the process interface.
v2.11.0-B4
Meaning
device was switched on. A 32-bit wide counter (0 - 4294967295) is
used, which starts again at 0 after reaching the maximum.
If this selection is activated, the total result or the partial result of the
job is transferred.
Result (2 characters):
1. Characters: "P" or "F" for a Pass or Fail result
2. Characters: "A" or space for "Alarm triggered" or "No alarm
triggered". 
Partial result (1 character):
"P" or "F" for a Pass or Fail result
"I" if the partial result was not output during the job
If this option is activated, the statistics for the result are included. The
total number of images, the number of OK images and the number of
images for the total result that triggered an alarm are all transferred,
with the individual values separated with a separator.
If this selection is activated, the string transferred via the TD command
is mirrored back as a control option.
If this selection is activated, a 16 bit wide counter (0-65535) is used.
This increases by 1 with each image acquired and resets to 0 once it
reaches 65535.
75/429
Technical Documentation
VeriSens
Baumer Optronic GmbH
Radeberg, Germany
®