15.4.17 TI command - trigger immediately

This function enables you to immediately trigger image acquisition and request a response datagram if
required (any configured trigger delay is ignored). The response datagram will only be sent if the result is
automatically sent following image evaluation and if the data is defined.
Example
Structure of the command PLC
Command
Parameters
T
I
Trigger
none
Immediately
Structure of the Response PLC
Response
R
D
0
0
Response
4 byte ASCII
Data
hex
Length of the
result data
NOTE
Further information on the composition of the datagram can be found using the command
"Retrieve last result (GD / RD)".
v2.11.0-B4
device
device
...
0
E
Data
330/429