6.
Select the PROFINET protocol.
7.
Reset the network settings to the initial state.
8.
Restart the Vision Sensor.
NOTE
It is not essential to reset the network settings to the initial state. A normal PROFINET
device does not have any IP address (0.0.0.0) in the factory settings and the IP address
is (permanently or temporarily) assigned by the PLC.
The Application Suite  Device settings or the Siemens PLC software package can
always be used to configure the PROFINET network and device name settings.
v2.11.0-B4
352/429
Technical Documentation
VeriSens
Baumer Optronic GmbH
Radeberg, Germany
®