Parameters
0
0
B
6
B
8 byte ASCII hex
Length of the following data
NOTE
If using DHCP, you can set what happens following a DHCP timeout as follows:
The response datagram is only sent once the backup has been transferred and stored in full or an error
occurs.
Structure of the Response PLC
Response
R
U
0
Response
2 byte ASCII hex
Update
00 = received OK
01 = device not in Configuration mode
02 = invalid job number
03 = job could not be loaded
04 = job update still active
05 = invalid network settings
06 = invalid device name
07 = backup file device type not identical to the device
08 = user management is active
09 = device file is password protected
10 = file could not be opened for writing
11 = file write error
12 = incompatible backup
13 = only the firmware cannot be imported
other = internal fault
v2.11.0-B4
...
B
4
6
Data of the
backup
device
Use DHCP and in case of DHCP failure, use the last IP address
UDD000.000.000.000000.000.000000.000.000...
or
UDD255.255.255.255000.000.000000.000.000...
Use DHCP, set an alternative IP address
e.g. UDD192.168.000.250255.255.255.000000.000.000.000...
(In this case, the alternative IP address is 192.168.0.250)