9 Creating a job

Jobs are created in three main steps, using the Job bar. The individual parameters can be set in this bar.

9.1 Adjusting the image (image focus)

To implement reliable inspection with the Vision Sensor, the features to be inspected must be clearly visible.
Set the image focus directly on the Vision Sensor installed at
the check location using an Allen key.
ATTENTION!
On devices with protection class IP 69K,
the setting screw is protected from
moisture by a sealing screw.
Do not remove the sealing screw in damp
rooms and only remove it for a short
amount of time as there are drying
capsules on the inside that absorb
moisture and may become saturated.
Reseal the setting screw with the sealing
screw once you have configured the image
focus!
For devices with interchangeable lenses, the image focus is set
on the installed lens.