15.4.8 GM command – access information about the device
This function enables you to access information about the connected device.
Example
Structure of the command PLC
Command
Parameters
G
M
0
Get Model
4 byte ASCII hex
Information
Access single elements
0001 = Device type
0002 = MAC address
0004 = Serial number
0008 = Firmware version
0010 = Hardware version
0020 = Device name
0040 = Manufacturer
0000 = All (in the order given above)
Structure of the Response PLC
Response
R
M
0
Response
4 byte ASCII hex
Model
mirrored parameters of the
Information
GM request
v2.11.0-B4
device
0
4
0
device
0
4
0
0
4 byte ASCII hex
For each element:
Length of the result data
0
1
4
Baumer Optronic GmbH
Data
315/429
Technical Documentation