If the feature check is to be corrected by the result of the part location, you can choose this option
here. External teach also makes it possible to retrain the feature check. Select the appropriate option
for this purpose.
Confirm your settings and return to the feature list with OK. Return to the feature list without making
any changes with Cancel.
This feature check has the following output values for the datagram at the process interface:
Output value
Result
Reference area brightness Integer
Colour deviation (ΔE)
Colour (Lab)
Colour (RGB)
Colour (HSV)
Colour (LCh)
v2.11.0-B4
Data type
Description
Result of the feature check: "P" (Pass); "F" (Fail)
Integer
Triple integer
Triple integer
Triple integer
Triple integer