Baumer VeriSens ID Series Technical Documentation Manual page 169

Vision sensor
Hide thumbs Also See for VeriSens ID Series:
Table of Contents

Advertisement

Position: Determine the switching points of the position.
Diameter: Determine the switching points for the diameter.
Roundness: Determine the switching points of the roundness.
The right button is used to invert the result of the feature check.
If you wish to change the reference position of the centre of the circle, simply press the Teach button
and the new position will be adopted.
Min. edge length: With short, medium long or user defined, select the anticipated length of the
sought contour to achieve a consistent result. Using User defined, you may manually enter the
length of an edge (5-1000 pixels).
Transition: You must specify whether each edge can progress from bright to dark or from dark to
bright (device dependant).
Minimum contrast: You can also specify whether you are searching for an edge with sharp or weak
contrast.
Direction: Select the direction of the search.
If the feature check is to be corrected by the result of the part location, you can choose this option
here. External teach also makes it possible to retrain the feature check. Select the appropriate option
for this purpose.
v2.11.0-B4
169/429
Technical Documentation
VeriSens
Baumer Optronic GmbH
Radeberg, Germany
®

Advertisement

Table of Contents
loading

Table of Contents