A match of the objects found will be directly displayed as a Match in the dialogue.
The switching point designated Min is adjusted on the right hand side. A graphic display is located in
the middle, in which the positions of the switching points are displayed and where they can be
changed. The upper bar shows the object with the highest match and the lower bar the object with
the lowest match.
Contrast: Set the minimum contrast of the contours that should be adopted in the model.
Form: Select the shape of the contour that equates to the test object. (Limiting the angular range
reduces processing time.)
Mode: Set the amount of detail to be used in the inspection. (The more detailed the mode, the
higher the processing time.)
Max. rotation: If you want to find the object only in a limited angular range, you may specify the
maximum rotational position here.
Maximum number of objects: This is where you configure the maximum number of objects to be
found. (Select the number to be as low as possible to reduce computation time.)
NOTE
Objects are more stable if they have contours that:
Restricting the detection area: If you do not wish to search for the object in the entire image, set the tick
and then limit the detection area.
Using additional tests: Enable this function if you want to conduct additional tests in the immediate
surroundings of each located object. These tests are then to be configured on the corresponding tab.
v2.11.0-B4
have no parallel lines spaced up to 4 pixels
are long (at least 20 pixels)
have a slight curvature