Timing diagram for SP and TE commands
The SP and TE commands can be sent at any time and are buffered. The system simultaneously sets a flag
to prevent further images from being acquired.
This means that all processes currently running are completed before a new one is triggered.
Example 1 (sequential processing)
All processes are completed up to result output 1. SP/TE then becomes effective.
1
SP / TE command
2
Trigger permitted
3
Trigger
4
Image acquisition
5
Image processing
6
Result
7
Value stored < 1 ms
Example 2 (overlapped, clocked processing)
The command comes after the second trigger → all processes up to trigger 1 and trigger 2 are completed,
SP/TE become effective after result 2.
1
SP / TE command
2
Trigger permitted
3
Trigger
4
Image acquisition
5
Image processing
6
Result
7
Value stored < 1 ms