Protocol (RS485) (device dependant)
Here, you will find all parameters which can be used to configure data exchange via the RS485 interface.
Select device number 1 and the "Bus (without checksum)" protocol type and adjust the other parameters as
necessary.
Baud rate: Speed of data transfer (bit/s).
Data bits: Number of bits per character
Device number: If you have multiple devices on one RS485 bus, each device must be assigned a number.
(1-254)
Receipt timeout: Here, you can set the time after which receipt is stopped.
Response delay: Duration between reception of a command and transmission of the response
RS485 terminating resistor: Disable the terminating resistor if more than 6 devices are being operated on
an RS485 bus.
Parity: Control of the parity bit
Stop bits: Number of stop bits as end code (1)
Protocol: Protocol type (point-to-point, bus without checksum, bus with checksum)
Protocol (PROFINET) (integrated, device dependant)
Here you will find all parameters which can be used to configure data exchange directly over the embedded
PROFINET interface. As a rule this generally only relates to changing the IP address to 0.0.0.0. There is also
the option of editing the device's PROFINET name. Although this should be assigned using the PROFINET
tool and not edited on the device.
NOTE
Once the request has been confirmed and the IP address and subnet mask have been
set to 0.0.0.0 the device can never again be accessed via the Application Suite and
can no longer be reconfigured in this manner. The FTP connection and web interface
communication will also be set.
The device can only be accessed via the Application Suite again if a PROFINET tool is
used to reconfigure it to an IP address other than 0.0.0.0
Device name: The device name is usually assigned by the PROFINET tool. There is the option here for
changing the device name in exceptional cases.
Datagram (RD)
Time:
Automatically following image analysis: the device sends the datagram independently
GD command via process interface: the device's result is requested with the GD command