15.4.4 Command GB – access device backup
NOTE
The backup functionality of the XF800 / XF900 vision sensors is only available via the
Application Suite.
This function enables you to access a backup of the device with firmware or the job as well as the device
settings.
Example
Structure of the command PLC
Command
Parameters
G
B
0
Get
0000 = Backup with firmware
Backup
0001 = Only jobs and device settings
Structure of the Response PLC
Response
R
B
0
Response
4 byte ASCII hex
Backup
Parameters of the GB-
command
Error messages:
F001 = Device is not
F004 = Backup has already
F008 = Password protection
(device dependant)
NOTE
If the device backup contains calibrated lens distortion or shading correction, then the
backup will only be completed when the Application Suite has been used to switch the
device to set-up mode after recovery (Device configuration).
Switching via the SM command is insufficient for this.
v2.11.0-B4
device
0
0
0
device
0
0
0
deactivated
been called
activated
0
0
0
4
F
8 Byte ASCII-Hex data length
(32bit)
For errors, the length is 0