Associating The Iterator Profile With Meps For Eth-Slm - Juniper ACX1000 Configuration Manual

Junos os; acx series universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

Associating the Iterator Profile with MEPs for ETH-SLM

Copyright © 2017, Juniper Networks, Inc.
Chapter 34: Configuring Operations, Administration, and Management (OAM)
Configure the measurement type as synthetic loss measurement.
6.
[edit protocols oam ethernet connectivity-fault-management performance-monitoring
sla-iterator-profiles i1]
user@host# set measurement-type slm
Configure the
disable
statement to stop the iterator (that is, disable the iterator profile).
7.
[edit protocols oam ethernet connectivity-fault-management performance-monitoring
sla-iterator-profiles i1]
user@host# set disable
Verify the configuration.
8.
[edit protocols oam ethernet connectivity-fault-management performance-monitoring
sla-iterator-profiles]
user@host# show i1
cycle-time cycle-time-value;
iteration-period iteration-period-value;
measurement-type slm;
You can associate a remote maintenance association end point (MEP) with more than
one iterator profile.
To configure a remote MEP with an iterator profile:
In configuration mode, go to the following hierarchy level:
1.
user@host# edit protocols oam ethernet connectivity-fault-management
maintenance-domain md-name maintenance-association ma-name mep mep-id
Configure the remote MEP ID with a value from 1 through 8191.
2.
[edit protocols oam ethernet connectivity-fault-management maintenance-domain
md-name maintenance-association ma-name mep mep-id]
user@host# set remote-mep remote-mep-id
Set the iterator profile.
3.
[edit protocols oam ethernet connectivity-fault-management maintenance-domain
md-name maintenance-association ma-name mep mep-id remote-mep
remote-mep-id]
user@host# set sla-iterator-profile profile-name
(Optional) Set the size of the data TLV portion of the Y.1731 data frame with a value
4.
from 1 through 1400 bytes. The default value is 1.
[edit protocols oam ethernet connectivity-fault-management maintenance-domain
md-name maintenance-association ma-name mep mep-id remote-mep remote-mep-id
sla-iterator-profile profile-name]
user@host# set data-tlv-size size
1155