NOTE:
In ACX Series routers, RFC 2544 tests are supported only for E-LINE,
ELAN, and EVPL services.
ACX5048 and ACX5096 routers supports only E-LINE services. ACX5048
and ACX5096 routers do not support family inet based reflection. Family
bridge and family CCC are supported.
Layer 2 and Layer 3 RFC 2544-Based Benchmarking Test Overview on page 1338
Configuring RFC 2544-Based Benchmarking Tests on page 1341
show services rpm rfc2544-benchmarking on page 3156
show services rpm rfc2544-benchmarking test-id on page 3161
In ACX Series routers, RFC 2544-based benchmark tests can be run to measure the
performance characteristic of the E-LINE, E-LAN, and EVPL services.
NOTE:
ACX5048 and ACX5096 routers supports only E-LINE services.
ACX5048 and ACX5096 routers do not support family inet based reflection.
Family bridge and family CCC are supported.
You can configure the test on the following underlying services:
Between two IPv4 endpoints—In this mode, the generator sends test packets to
user-configured IP destination or UDP port (which is of the reflector).
Between two user-to-network interfaces (UNIs) of Ethernet Virtual Connection
(EVC), Ethernet Private Line (EPL, also called E-LINE), Ethernet Virtual Private Line
(EVPL), EVC (EPL, EVPL)—One end is configured as the generator or initiator and
the other end acts as the reflector. The generator receives the test packets that are
returned from the reflector and computes the test results.
NOTE:
Benchmarking tests are not supported for IPv6-based services.
You cannot perform multiple simultaneous RFC 2544-based benchmarking tests on
the same pseudowire.
Interoperation of the RFC 2544 benchmarking tests with other third-party customer
premises equipment (CPE) that provides embedded or dedicated benchmarking test
capability is not supported.
Fragmented test-frames and one-way measurements of frames are not supported.
You must configure one end or the source device to initiate and terminate test frames