ACX Series Universal Access Router Configuration Guide

asymmetry

Syntax
Hierarchy Level
Release Information
Description
Options
Required Privilege
Level
Related
Documentation
1434
asymmetry number
For ACX Series and QFX Series:
[edit protocols ptp
slave interface unicast-mode clock-source
For MX Series:
[edit protocols ptp slave interface interface-name multicast-mode],
[edit protocols ptp master interface interface-name multicast-mode]
Statement introduced in Junos OS Release 15.2 for MX Series routers.
Statement introduced in Junos OS Release 17.3 for QFX Series switches.
Specify the asymmetry value between the master and the slave. A compensating value
for networks in which there is path asymmetry between the 1588v2 slave and master.
Specify a positive or negative value that is added to the path delay value from the slave
to the master, making the delay symmetric and equal to the path from the master to the
slave.
number—The asymmetry value is in nanoseconds and can vary from minus (–)100
milliseconds to 100 milliseconds, allowing compensation for up to 1/10 of a second
of path asymmetry.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
IEEE 1588v2 Precision Timing Protocol (PTP) on ACX Series Universal Access Routers
on page 237
Precision Time Protocol Overview
Configuring Precision Time Protocol
Example: Configuring Precision Time Protocol
local-ip-address]