ACX Series Universal Access Router Configuration Guide
Table 100: jnxSoamDmThresholdCfgTable (continued)
Object
1222
Object ID
Description
Contains a vector of bits that indicates
the type of SOAM DM thresholds
notifications that are enabled. A bit set
to '1' enables the specific SOAM DM
threshold notification and when the
specific counter is enabled and the
threshold is crossed a notification is
generated. A bit set to '0' disables the
specific SOAM DM threshold notification.
If a particular SOAM DM threshold is not
supported the BIT value is set to '0'.
b J n x S o a m D m M e a s u r e d F r a m e D e l a y T w o W a y T h r e s h o l d ( 0 ) — E n a b l e s
or disables measured frame two-way
delay threshold notification. The
notification is sent immediately when the
jnxSoamDmMeasuredStatsFrameDelayTwoWay
value is greater than or equal to threshold
value.
b J n x S o a m D m M a x F r a m e D e l a y T w o W a y T h r e s h o l d ( 1 ) — E n a b l e s
or disables maximum frame two-way
delay threshold notification. The
notification is sent immediately when the
jnxSoamDmCurrentStatsFrameDelayT woWayMax
value is greater than or equal to threshold
value in a Measurement Interval.
b J n x S o a m D m A v g F r a m e D e l a y T w o W a y T h r e s h o l d ( 2 ) — E n a b l e s
or disables average frame two-way delay
threshold notification. The notification is
sent when at the end of a Measurement
Interval if the
jnxSoamDmCurrentStatsFrameDelayT woWayAvg
value is greater than or equal to the
threshold value.
b J n x S o a m D m M e a s u r e d I f d v T w o W a y T h r e s h o l d ( 3 ) — E n a b l e s
or disables measured frame IFDV
two-way threshold notification. The
notification is sent immediately when the
jnxSoamDmMeasuredStatsIfdvTwoWay
value is greater than or equal to threshold
value.
bJnxSoamDmMaxIfdvT woW ayThreshold( 4)—Enables
or disables maximum frame IFDV
two-way threshold notification. The
notification is sent immediately when the
jnxSoamDmCurrentStatsIfdvTwoWayMax
value is greater than or equal to threshold
value in a Measurement Interval.
bJnxSoamDmAvgIfdvT woW ayThreshold(5)—Enables
or disables average frame IFDV two-way
threshold notification. The notification is
sent when at the end of a Measurement