Bandwidth (Tunnel Services) - Juniper ACX1000 Configuration Manual

Junos os; acx series universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

bandwidth (Tunnel Services)

Syntax
Hierarchy Level
Release Information
Description
Options
Required Privilege
Level
Related
Documentation
Copyright © 2017, Juniper Networks, Inc.
bandwidth bandwidth-value;
[edit chassis fpc slot-number pic number tunnel-services]
Statement introduced in Junos OS Release 8.2.
Statement introduced in Junos OS Release 12.3X54 for ACX Series routers.
(ACX Series, MX Series 3D Universal Edge Routers and T4000 Core Routers only) Specify
the amount of bandwidth in gigabits per second to reserve for tunnel services. For ACX
Series routers, you can configure a bandwidth of only 1 Gbps and 10 Gbps for logical
tunnel (lt-) interfaces.
bandwidth-value—Amount of bandwidth in Gbps to reserve for tunnel services. On MX
Series routers, the bandwidth values can be
T4000 routers, the bandwidth values are multiples of
NOTE:
The bandwidth that you specify determines the port number of the
tunnel interfaces that are created. When you specify a bandwidth of
port number is always 10. When you specify any other bandwidth, the port
number is always 0.
NOTE:
If you specify a bandwidth that is not compatible with the type of
DPCs or MPCs and their respective Packet Forwarding Engine, tunnel services
are not activated. For example, you cannot specify 1 gigabit per second
bandwidth for a Packet Forwarding Engine on a 10-Gigabit Ethernet 4-port
DPC or 16x10GE 3D MPC.
When the tunnel bandwidth is unspecified in the Routing Engine CLI, the
maximum tunnel bandwidth for MPC3E is 60G.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Example: Configuring Tunnel Interfaces on a Gigabit Ethernet 40-Port DPC
Tunnel Interface Configuration on MX Series Routers Overview
Configuring Tunnel Interfaces on T4000 Routers
Example: Configuring Tunnel Interfaces on a 10-Gigabit Ethernet 4-Port DPC
Example: Configuring Tunnel Interfaces on the MPC3E
Chapter 41: Configuration Statements
1g
and multiples of
10g
up to
up to
.
10g
100g
100g
. On
, the
1g
1449

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acx5048Acx5096Acx500Acx1100Acx2000Acx2100 ... Show all

Table of Contents