1352
To configure a test name and define its attributes for reflector:
NOTE:
In ACX5048 and ACX5096 routers, while performing RFC 2544
benchmark test, you must ensure that there are no configurations associated
with the reflector port.
In configuration mode, go to the
1.
[edit]
user@host# edit services
Configure an RPM service instance.
2.
[edit services]
user@host# edit rpm
Configure an RFC 2544-based benchmarking test for the RPM instance.
3.
[edit services rpm]
user@host# edit rfc2544-benchmarking
Define a name for the test—for example, test1. The test name identifier can be up to
4.
32 characters in length.
[edit services rpm rfc2544-benchmarking]
user@host# edit tests test-name test1
Specify the test mode for the packets that are sent during the benchmarking test. The
5.
option causes the test frames to be reflected back to the intiator end..
reflect
[edit services rpm rfc2544-benchmarking tests test-name test1]
user@host# set mode reflect
Specify the family for the benchmarking test.
6.
[edit services rpm rfc2544-benchmarking tests test-name test1]
user@host# set family bridge
Specify the direction (
7.
egress | ingress
The
option causes the test to be run in the egress direction of the interface
egress
(traffic sent from user-to-network interface (UNI) toward network-to-network
interface (NNI)). The
ingress
of the interface (traffic sent on user-to-network interface (UNI)). You cannot configure
for a bridge family.
ingress
[edit services rpm rfc2544-benchmarking tests test-name test1]
user@host# set direction egress
Configure the destination IPv4 address for the test packets. This parameter is required
8.
only if you configure an IPv4 family inet. This option is not required if you specify circuit
hierarchy level.
[edit services]
) of the interface on which the test must be run.
option causes the test to be run in the ingress direction