Table 91: jnxSoamLmCfgTable (continued)
Object
jnxSoamLmCfgMessagePeriod
jnxSoamLmCfgPriority
jnxSoamLmCfgFrameSize
Copyright © 2017, Juniper Networks, Inc.
Chapter 34: Configuring Operations, Administration, and Management (OAM)
Object ID
Description
jnxSoamLmHistoryStatsBackwardAvgFlr counters.
bSoamPdusSent (10)—Enables or disables the
jnxSoamLmCurrentStatsSoamPdusSent and
jnxSoamLmHistoryStatsSoamPdusSent counters.
bSoamPdusReceivedbReceivedMeasurements
(11)—Enables or disables the
jnxSoamLmCurrentStatsSoamPdusReceived and
jnxSoamLmHistoryStatsSoamPdusReceived counters.
bMeasuredStatsForwardMeasuredFlr(26)—Enables or
disables the jnxSoamLmMeasuredStatsForwardFlr
counter.
bMeasuredStatsBackwardMeasuredFlr(27)— Enables
or disables the jnxSoamLmMeasuredStatsBackwardFlr
counter.
Specifies the interval between Loss Measurement OAM
JnxSoamLmCfgEntry
message transmission. For Loss Measurement monitoring
6
applications the default value is 1 sec.
This object is not applicable if jnxSoamLmCfgType is set
to lmCcm and is ignored for that Loss Measurement Type.
This object can only be written at row creation time and
cannot be modified once it has been created.
Specifies the Loss Measurement OAM message priority
JnxSoamLmCfgEntry
and the priority of the service OAM traffic to be monitored.
7
Only frames of the same Class of Service are counted.
The default value is to be the value which yields the lowest
frame loss.
This object is not applicable if jnxSoamLmCfgType is set
to lmCcm.
This object can only be written at row creation time and
cannot be modified once it has been created.
Specifies the Loss Measurement frame size between 64
JnxSoamLmCfgEntry
bytes and the maximum transmission unit of the EVC. The
8
range of frame sizes from 64 through 2000 octets need
to be supported, and the range of frame sizes from 2001
through 9600 octets is suggested be supported.
The adjustment to the frame size of the standard frame
size is accomplished by the addition of a Data or Test TLV.
A Data or Test TLV is only added to the frame if the frame
size is greater than 64 bytes.
This object is only valid for the entity transmitting the Loss
Measurement frames, type 'lmSlm', and is ignored by the
entity receiving frames. It is not applicable for the 'lmCcm'
or 'lmLmm' types.
This object can only be written at row creation time and
cannot be modified once it has been created.
1179