ACX Series Universal Access Router Configuration Guide
Table 95: jnxSoamDmCfgTable (continued)
Object
jnxSoamDmCfgRepetitionTime
jnxSoamDmCfgAlignMeasurementIntervals
1204
Object ID
jnxSoamDmCfgEntry 16
jnxSoamDmCfgEntry 17
Description
Specifies a configurable repetition time
between Measurement Intervals in a Delay
Measurement session in seconds. If the value
is 0 (none), there is no time gap between
the end of one Measurement Interval and
the start of a new Measurement Interval.
This is the normal usage case. If the value is
greater than one Measurement Interval there
is time gap between the end of one
Measurement Interval and the start of the
next Measurement Interval. The repetition
time specifies the time between the start of
consecutive Measurement Intervals; hence
the gap between the end of one
Measurement Interval and the start of the
next is equal to the difference between the
repetition time and the measurement
interval. During this gap, no SOAM PDUs are
sent for this session and no measurements
are made. If the value is greater 0 but less
than or equal to the measurement interval,
an error is returned.
This object can only be written at row
creation time and cannot be modified once
it has been created.
Specifies whether the Measurement
Intervals for the Delay Measurement session
are aligned with a zero offset to real time.
The value 'true' indicates that each
Measurement Interval starts at a time which
is aligned to NE time source hour, if the
repetition time (or the Measurement Interval,
if the repetition time is 0) is a factor of an
hour, that is, 60min/15min = 4. For instance,
a Measurement Interval/repetition time of
15 minutes would stop/start the
Measurement Interval at 0, 15, 30, and 45
minutes of an hour. A Measurement
Interval/Repetition Time of 7 minutes would
not align to the hour since 7 minutes is NOT
a factor of an hour, that is, 60min/7min =
8.6. In this case the behavior is the same as
if the object is set to 'false'.
The value 'false' indicates that the first
Measurement Interval starts at an arbitrary
time and each subsequent Measurement
Interval starts at a time which is determined
by jnxSoamDmCfgRepetitionTime.
This object can only be written at row
creation time and cannot be modified once
it has been created.