Table 90: jnxSoamPmMepTable (continued)
Object
jnxSoamPmMepDmSingleEndedResponder

Managed Objects for jnxSoamLmCfgTable

Table 91: jnxSoamLmCfgTable
Object
jnxSoamLmCfgIndex
1174
Object ID
jnxSoamPmMibObjects
4
The
, whose object identifier is
jnxSoamLmCfgTable
the
that signifies the Ethernet loss measurement (ETH-LM)
jnxSoamLmCfgEntry
configuration settings. Each
, contains the objects listed in the following table.
{jnxSoamLmCfgTable 1}
The
jnxSoamLmCfgTable
includes configuration objects and operations for the frame
loss measurement function defined in [Y.1731] and [MEF SOAM-PM]. Each row in the
table represents a Loss Measurement session for the defined MEP. This table uses four
indices. The first three indices are the indices of the Maintenance Domain, MaNet, and
MEP tables. The fourth index is the specific LM session on the selected MEP. A Loss
Measurement session is created on an existing MEP by first accessing the
jnxSoamPmMepOperNextIndex object and using this value as the jnxSoamLmCfgIndex
in the row creation.
Some writable objects in this table are only applicable in certain cases (as described
under each object), and attempts to write values for them in other cases will be ignored.
The writable objects in this table need to be persistent upon reboot or restart of a device..
Object ID
JnxSoamLmCfgEntry
1
Description
This object specifies whether the Delay Measurement
(DMM) single-ended Responder is enabled.
The value of
true
Measurement Responder is enabled and if a DMM
message is received a DMR is sent in reply. The value
of
indicates the single-ended Delay Measurement
false
Responder is disabled. If a DMM message is received,
no response is sent and the message is discarded.
This object needs to be persistent upon reboot or
restart of a device. A MEP can be both a single-ended
Responder and Controller simultaneously.
{jnxSoamPmLmObjects 1}
jnxSoamLmCfgEntry
, whose object identifier is
Description
Denotes an index to the Loss Measurement Configuration
table which indicates the specific measurement session
for the MEP.
jnxSoamPmMepOperNextIndex needs to be inspected to
find an available index for row-creation.
Referential integrity is necessary (that is, the index needs
to be persistent upon a reboot or restart of a device. The
index is never reused for other PM sessions on the same
MEP while this session is active. The index value keeps
increasing until it wraps to 0. This is to facilitate access
control based on a fixed index for an EMS, since the index
is not reused.
indicates the single-ended Delay
, contains
Copyright © 2017, Juniper Networks, Inc.