Juniper ACX1000 Configuration Manual page 961

Junos os; acx series universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

Requirements
Overview
Configuration
CLI Quick
Configuration
Copyright © 2017, Juniper Networks, Inc.
NOTE:
This example is not applicable on ACX5048 and ACX5096 routers.
Requirements on page 903
Overview on page 903
Configuration on page 903
This example uses the following hardware and software components:
ACX Series router
Junos OS Release 12.2 or later
A previously configured ATM IMA pseudowire. For steps to configure an ATM IMA
pseudowire, see
"Configuring Inverse Multiplexing for ATM (IMA)" on page
In this example, an ATM IMA pseudowire logical interfaces (
two egress ATM shapers—
with the following parameters:
—ATM service category used to define the bit rate at which traffic is policed.
atm-service
—Top rate at which traffic can burst. This is a mandatory statement that
peak-rate
must be included for the configuration to work correctly.
—Normal traffic rate averaged over time.
sustained-rate
—Maximum number of cells that a burst of traffic can contain.
maximum-burst-size
In addition to the configuration of shaping, this example includes the configuration of
tracing operations for the class-of-service (CoS) configuration.
To configure shaping on an ATM IMA pseudowire, perform these tasks:
Configuring Shaping on an ATM IMA Pseudowire on page 904
Configuring Tracing Operations on page 905
Results on page 906
To quickly configure this example, copy the following commands, paste them in a text
file, remove any line breaks, change any details necessary to match your network
configuration, and then copy and paste the commands into the CLI at the [
level:
set class-of-service traffic-control-profiles profile-1 atm-service rtvbr
set class-of-service traffic-control-profiles profile-1 peak-rate 5k
set class-of-service traffic-control-profiles profile-1 sustained-rate 3k
set class-of-service traffic-control-profiles profile-1 max-burst-size 400
and
. The ATM shaping profiles are configured
profile-1
profile-2
Chapter 27: Configuring Class of Service
185.
) is configured with
unit 0
] hierarchy
edit