Overview; Endpoint Independent Flow For Napt - Juniper ACX1000 Configuration Manual

Junos os; acx series universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

Related
Documentation
Configuring Address Pools for Network Address Port Translation (NAPT) Overview

Endpoint Independent Flow for NAPT

Copyright © 2017, Juniper Networks, Inc.
Chapter 31: Configuring Network Address Translation (NAT) and Stateful Firewall Services
NOTE:
When configuring NAT, if any traffic is destined for the following
addresses and does not match a NAT flow or NAT rule, the traffic is dropped:
Addresses specified in the source NAT pool when you are using source
translation
Network Address Translation Overview on page 999
Network Address Port Translation Overview on page 1001
Enabling Inline Services Interface on ACX Series on page 1008
Understanding Service Sets on page 1028
Network Address Translation Address Overload in ACX Series on page 1001
CoS for NAT Services on ACX Series Universal Access Routers on page 887
Network Address Translation Constraints on ACX on page 1003
Configuring Address Pools for Network Address Port Translation (NAPT) Overview on
page 1007
Network Address Translation Rules Overview on page 1004
With Network Address Port Translation (NAPT), you can have up to 4096 network
address or port translations.
The
statement specifies port assignment for the translated addresses. To configure
port
a specific range of port numbers, include the
statement at the
maximum-value
Junos OS for ACX Series routers allocates ports sequentially—that is, ACX Series routers
allocate the first available address or port from the NAT pool.
The NAT pool called
napt
implementation:
pool napt {
address-range low 100.0.0.1 high 100.0.0.3;
port {
range low 49160 high 53255;
}
}
Endpoint Independent Flow for NAPT on page 1007
Endpoint independent flow ensures the assignment of the same external address and
port for all connections from a given host or port to any destination. This means if the
port range low minimum-value high
[edit services nat pool nat-pool-name]
in the following configuration example uses the sequential
hierarchy level.