Error Messages in GP-GL Command Mode
Error
LCD Display
Displayed
E02001
E02004
E02005
E02006
Cause
The plotter received an unrecognizable
command.
Nose came n when the computer was
turned on.
The software configuration regarding the
output devce has been changed.
The plotter's nterface condtons have
changed.
A command was receved contanng
numerc parameters that exceed that
command's permssble range.
The software configuration regarding the
output devce has been changed.
The plotter's nterface condtons have
changed.
An error occurred n the recept of data
wthn the nterface.
The software configuration regarding the
output devce has been changed.
The plotter's nterface condtons have
changed.
The data out of cuttng range has been
receved.
12-6
Solution
Press the [ENTER] key.
Configure to drive the plotter from the menu
of the software.
Reset the nterface settngs of the software.
Reset the nterface settngs of the plotter.
Configure to drive the plotter from the menu
of the software.
Reset the nterface settngs of the software.
Reset the nterface settngs of the plotter.
Configure to drive the plotter from the menu
of the software.
Reset the nterface settngs of the software.
Reset the nterface settngs of the plotter.
Check the data.
Check the size of media and the cutting
range.
Check the magnification setting.
Check the step size settings.