9.5

Error Messages in GP-GL Command Mode

Error message
ERROR 1
Command Error
ERROR 4
Parameter Overflow
ERROR 5
I/O Error
FC4500-UM-251-9370
Cause
The plotter received an
unrecognizable command.
When turning on the plotter to
which your software application
has output data, noise mixed into
the data input.
Your software application's output
device setting has changed.
The plotter's interface conditions
have changed.
The numeric parameter of an input
command exceeds its permissible
range.
Your software application's output
device setting has changed.
The plotter's interface conditions
have changed.
An error related to the receipt of
data occurred within the interface.
Your software application's output
device setting has changed.
The plotter's interface conditions
have changed.
146
9 TROUBLE SHOOTING
Solution
Press the plotter's ENTER key.
Configure your software application
menu to permit Graphtec plotter control.
Re-specify the software application's
interface conditions.
Re-specify the plotter's interface
conditions.
Configure your software application
menu to permit Graphtec plotter control.
Re-specify the software application's
interface conditions.
Re-specify the plotter's interface
conditions.
Configure your software application
menu to permit Graphtec plotter control
Re-specify the software application's
interface conditions..
Re-specify the plotter's interface
conditions.