8.4.2 Error Messages in GP-GL Command Mode

Error
Error Display
code
E02001
E02001 GP-GL
ERROR 1
COMMAND ERROR!
E CONFIRM
E02004 E02004 GP-GL
ERROR 4
PARAMETER OVERFLOW!
E CONFIRM
E02005
E02005 GP-GL
ERROR 5
I/O ERROR!
E CONFIRM
FC8000-UM-251-9370
Cause
Verification item
The plotter
(1) Did the plotter
received an
receive an
unrecognizable
unrecognizable
command.
command?
(2) Is there any noise
on the line?
(3) Has the correct
model name been
set for the plotter?
• The software
The numeric parameter
configuration
of an input command
regarding the
exceeds its permissible
output device
range.
An error related to the
has been
receipt of data occurred
changed.
within the interface.
• The plotter's
interface
conditions
have been
changed.
8-7
8. TROUBLESHOOTING
Solution
No .....Verify item (2)
Yes . ...Send correct data
to plotter.
No .....Verify item (3)
Yes . ...Check the
interface cable or
move the plotter to
another location.
No .....Set the correct
model name.
Configure your software
application menu to
permit Graphtec plotter
control. Re-specify the
software application's
interface conditions.
Configure your software
application menu to
permit Graphtec plotter
control. Re-specify the
software application's
interface conditions.
Set the correct model
name if it was incorrect.