9.3.2 Error Messages in GP-GL Command Mode

Error message
ERROR 1
Command Error
ERROR 4
Parameter Overflow
ERROR 5
I/O Error
Cause
The plotter received an unrecog-
nizable command.
When turning on the plotter to which
your software application has out-
put data, noise mixed into the data
input.
Your software application's output
device setting has changed.
The plotter's interface conditions
have changed.
The numeric parameter of an input
command exceeds its permissible
range.
Your software application's output
device setting has changed.
The plotter's interface conditions
have changed.
An error related to the receipt of
data occurred within the interface.
Your software application's output
device setting has changed.
The plotter's interface conditions
have changed.
9 – 10
Solution
Press the plotter's ENTER key.
Configure your software applica-
tion menu to permit Graphtec plot-
ter control.
Re-specify the software applica-
tion's interface conditions.
Re-specify the plotter's interface
conditions.
Configure your software applica-
tion menu to permit Graphtec plot-
ter control.
Re-specify the software applica-
tion's interface conditions.
Re-specify the plotter's interface
conditions.
Configure your software applica-
tion menu to permit Graphtec plot-
ter control.
Re-specify the software applica-
tion's interface conditions.
Re-specify the plotter's interface
conditions.

Hide quick links: