PARALLEL MEMORY TRANSMISSION

2. PARALLEL MEMORY TRANSMISSION
Using basic memory transmission, normally the machine starts dialing after
the document has been completely scanned. Using Parallel Memory
Transmission, the machine starts dialing at the same time the machine starts
scanning. If the document has multiple pages, the machine scans them into
memory and sends them while scanning continues.
Note
This function is only usable when sending an original from the
ADF.
The following table shows the differences between normal memory
transmission and parallel memory transmission.
File Reserve Report
If the other terminal is busy
If transmission failed
If memory overflows during
scanning
If a document jam occurred
during scanning
How and when the scanned
message is erased from
memory
Memory threshold to start
scanning into memory
Meaning of the stamp mark
Batch numbering (P. x/x)
Including a sample of the
image on reports
SM
Normal memory tx
Printed, if automatic report
printout is enabled.
Tries to resend the message
later.
Tries to resend the remaining
pages later.
Stops scanning and erases
all the scanned pages from
memory, or sends all the
scanned pages (user's
choice).
Stops scanning and deletes
all the scanned pages from
memory.
The complete message is
erased after all the pages
have been sent.
Depends on the setting of
communication switch 0D.
Default setting - 24kB
Successfully stored.
Enabled
Possible
2-4
Parallel memory tx
Not printed.
Continues scanning the
document into memory, and
tries to resend it later.
Tries to resend the remaining
pages later.
Stops scanning and hangs
up the communication when
memory overflow is detected.
Then erases all the scanned
pages from memory without
notifying the user.
Stops scanning and hangs
up the communication when
a document jam is detected.
Same as memory
transmission.
Depends on the setting of
system switch 10.
Default setting - 512 kB
Successfully stored.
Not available unless the
number of pages is
programmed manually.
Possible
(A639)