SC123: Scanner home position error 4
-Definition- [B]
The scanner home position sensor does not detect the on condition after
the scanner returns to the home position.
- Possible causes -
Scanner home position sensor defective
Scanner drive motor defective
IOCSS board defective
Scanner home position senor harness defective
SC192: Automatic SBU adjustment error
-Definition- [B]
An error is detected during automatic SBU adjustment.
- Possible cause -
SBU defective
BiCU board defective
Lamp regulator defective
Exposure lamp deective
Dirty white plate
SC302: Charge roller current leak
-Definition- [B]
A charge roller current leak signal is detected.
- Possible causes -
Charge roller damaged
Charge high voltage supply board defective
Poor connection of the PCU
SM
SC CODE DESCRIPTIONS