Paper End And Upper Limit Sensor Replacement - Gestetner A193 Service Manual

Table of Contents

Advertisement

4.6 PAPER END AND UPPER LIMIT SENSOR REPLACEMENT

1. Remove the paper tray.
2. Remove the paper end and upper limit sensor with bracket [A] (1 screw, 2
connectors).
3. Replace the paper end sensor [B] or replace the upper limit sensor [C].
NOTE: When reinstalling the sensor ass'y, insert the harness into the clamp
to prevent the harness from touching the paper.
SM
REPLACEMENT AND ADJUSTMENT
[C]
[A]
[B]
8-13
G697O012.wmf
(G697)