FUSING/EXIT

6.3 HOT ROLLER/FUSING LAMP

[F]
[H]
[G]
[E]
[A]
1. Remove the fusing unit (1 screw).
2. Remove the front cover and upper cover. (See Fusing
Thermister/Thermofuse.)
3. Remove the front and rear pressure springs [A] after checking their
positions. (The standard setting is in the middle position.)
4. Remove the fusing stay [B] (5 screws).
5. Remove the front lamp holder [C] (1 screw).
6. Remove the fusing harness [D] (1 screw and 1 connector), pull the fusing
lamp [E] out forward, and keep it in a safe place.
7. Remove the hot roller [F].
NOTE: Do not touch the hot roller with bare hands.
8. Remove the front and rear C-rings [G], then remove the hot roller
bushings [H] and fusing gear [I].
NOTE: Do not touch the fusing lamp with bare hands.