SERVICE PROGRAM MODE TABLE
Mode No.
Class
Class 3
1 and 2
Memory Copy
5-945*
Priority
Auto Shut-off
Mode
Disabling
when there is
5-946*
paper in the
1-bin sorter
Use of 25%
Reduction
5-947*
Ratio in the
##
Photo and
Letter/Photo
Modes
AC Switch
Auto Shut Off
5-948*
##
VRAM Data
5-991*
Download
System
Parameter
5-992
and Data List
Printing
ADF Side-to
1
Side
Registration
ADF Leading
6-006 *
2
Edge
Registration
ADF Trailing
3
Erase Margin
ADF
Sub-scan
6-007*
Magnification
ADF Free Run Performs an ADF free run.
6-009
A224
Function
Selects whether or not the memory copy
mode is selected when the main switch is
turned on.
Selects whether the auto shut-off mode is
disabled or not when there is paper in the
1-bin sorter.
When the machine enters the auto shut-
off mode while there is paper in the 1-bin
sorter, the sorter paper indicator will go
off. If this is not acceptable, this SP mode
should be set at "1"
Determines whether a reduction ratio of
25% can be used in the Photo and
Letter/Photo modes (binary picture mode).
Selects whether the ac switch auto
shut-off mode or not.
If at "1", the ac switch turns off
automatically when entering the auto shut
off mode.
This SP mode is only used by the
designer.
Do not change the value.
Prints the machine status history data list.
See the "SYSTEM PARAMETER AND
DATA LISTS" section for how to print the
lists.
Adjusts the printing side-to-side
registration in the ADF mode.
Use the •/∗ key to toggle between + and -.
Adjusts the leading edge registration in
the ADF mode.
Use the •/∗ key to toggle between + and -.
Adjusts the trailing edge erase margin in
ADF mode.
Use the •/∗ key to toggle between + and -.
Adjusts the magnification in the sub-scan
direction for ADF mode.
Use the •/∗ key to toggle between + and -.
See "Replacement and Adjustment -
Copy Image Adjustments" for details.
To perform the free run, press 1 then
press
twice. Press
13-40
Settings
0: No
1: Yes
0: No
1: Yes
0: No (50% -
400%)
1: Yes (25% -
400%)
0: No (115V
Machine)
1: Yes (230V
machine)
0: Off
1: On
0: No Print
1: SP mode
2: UP mode
3: Log data
-1.5 ~ +1.5
0.5 mm/step
+ 0.0 mm
-10 ~ +10
0.5 mm/step
+ 6.0 mm
-3.0 ~ +3.0
0.1 mm/step
+ 0.0 mm
- 4.0 ~ + 4.0
0.1 %/step
0.0 %
0: No
1: Yes
to stop.