SERVICE RAM ADDRESSES
4801AC(H) - Optional equipment (Read only)
Bit 0: Page memory card
Bit 1: SAF memory card 2M
Bit 2: SAF memory card 4M
Bit 3: Not used
Bit 4: Hard disk
Bit 5: Function upgrade card
Bit 6: ISDN unit
Bit 7: Not used
4801C0 to 4801C2(H) - Tx counter
Address
4801C0(H)
4801C1(H)
4801C2(H)
4801C4 to 4801C6(H) - Rx counter (the format is the same as for the tx counter)
4802AE to 4802C5(H) - G4 terminal ID (ASCII - Max. 24 characters)
4802C6 to 4802D9(H) - ISDN G3 CSI (ASCII - Max. 20 digits)
4802DA(H) - Number of digits programmed in the ISDN G3 CSI (Hex)
4802DB to 4802DE(H) - ISDN IP
4802DF to 4802E2(H) - ISDN G3 sub-address
4802E3 to 4802E6(H) - ISDN G4 sub-address
4802E7 to 4802EB(H) - CiG4 board ROM information
4802E7(H) - Suffix
4802E8(H) - Version (BCD)
4802E9(H) - Year (BCD)
4802EA(H) - Month (BCD)
4802EB(H) - Day (BCD)
480300(H) - Number of copies for multi-sort document reception
480356(H) - Time for economy transmission (hour in 24h clock format - BCD)
480357(H) - Time for economy transmission (minute - BCD)
480372(H) - Transmission monitor volume
480373(H) - Reception monitor volume
480374(H) - On-hook monitor volume
480375(H) - Dialing monitor volume
480376(H) - Buzzer volume
480379 to 48037D(H) - Periodic service call parameters (Refer to section 2.1.2 for details)
480383 to 480385(H) - Effective term of automatic service calls (Refer to section 2.1.4 for
details)
480400 to 4804DA(H) - NCU parameters (Refer to section 4.3 for details)
SM
0: Not installed, 1: Installed
0: Not installed, 1: Installed
0: Not installed, 1: Installed
0: Not installed, 1: Installed
0: Not installed, 1: Installed
0: Not installed, 1: Installed
High
Tens digit
Thousands digit
Hundred thousands digit
4-72
Low
Unit digit
Hundreds digit
Ten thousands digit
00 - 07(H)
00 - 07(H)
00 - 07(H)
00 - 07(H)
00 - 07(H)
(A639)