Gestetner A193 Service Manual page 503

Table of Contents

Advertisement

SC503: Upper tray lift motor malfunction (optional paper tray unit only)
(A193/A224)
SC504: Lower tray lift motor malfunction (optional paper tray unit only)
(A193/A224)
-Definition- [C]
The paper upper limit sensor is not activated after the tray lift motor has been
on for 10 seconds.
- Possible causes -
Upper limit sensor defective
Tray lift motor defective
IOCSS board defective
SC506: Paper tray unit main motor lock (optional paper tray unit
only) (A193/A224)
-Definition- [C]
A main motor lock signal is detected for more than 5 seconds or the lock
signal is not detected for more than 5 seconds during rotation.
- Possible causes -
Paper tray unit main motor defective
Too much load on the drive mechanism
SC542: Fusing temperature warm-up error (A193/A224)
-Definition- [A]
The fusing temperature does not reach the fusing standby temperature within
50 seconds after the main switch is turned on.
- Possible causes -
Fusing thermistor defective or out of position
Fusing lamp open
Fusing thermofuse open
Power supply board defective
Poor connection of the fusing unit