Gestetner A193 Service Manual page 645

Table of Contents

Advertisement

Communication Switch 01
No
FUNCTION
6
Maximum printable page
length available
7
Bit 7 Bit 6
Setting
0
0
No limit
0
1
B4 (364 mm)
1
0
A4 (297 mm)
1
1
A3 (432 mm)
Communication Switch 02
No
FUNCTION
0 Burst error threshold
0: Low
1: High
1 Acceptable total error line
ratio
0: 5%
1: 10%
2 Treatment of pages received
with errors during G3
reception
0: Deleted from memory
without printing
1: Printed
3 Hang-up decision when a
negative code (RTN or PIN)
is received during G3
immediate transmission
0: No hang-up, 1: Hang-up
4
Not used
to
7
(A639)
COMMENTS
The setting determined by these bits is informed to the
transmitting terminal in the pre-message protocol
exchange (in the DIS/NSF frames).
COMMENTS
If there are more consecutive error lines in the received
page than the threshold, the machine will send a
negative response.
The Low and High threshold values depend on the
sub-scan resolution, and are as follows.
Resolution
100 dpi
3.85 l/mm
Low settings
3
High settings
6
If the error line ratio for a page exceeds the acceptable
ratio, RTN will be sent to the other end.
0: Pages received with errors are not printed.
0: The next page will be sent even if RTN or PIN is
received.
1: The machine will send DCN and hang up if it receives
RTN or PIN.
This bit is ignored for memory transmissions or if ECM
is being used.
Do not change the settings.
4-41
BIT SWITCHES
200 dpi
400 dpi
7.7 l/mm
15.4 l/mm
6
12
12
24
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

A224