12.1.2 Output Check (SP5-804)
CAUTION: To prevent mechanical or electrical damage, do not keep an
electrical component on for a long time.
1. Access SP mode 5-804.
2. Select the SP number that corresponds to the component you wish to
check (see the following table), then press
3. Press "1", then press
4. Exit the SP mode to interrupt the test.
5. If you wish to check another component, re-enter the SP mode.
- Output check table -
No.
Description
1
Junction Gate Solenoid
2
Registration Solenoid
3
Upper Relay Clutch
4
Lower Relay Clutch
5
Charge Roller Contact Clutch
By-pass Feed Clutch
6
Upper Paper Feed Clutch
7
-A193 only-
Lower Paper Feed Clutch
8
Development Clutch
9
Toner Bottle Drive Motor
10
Main Motor (Forward)
11
Main Motor (Reverse)
12
Exhaust Fan
13
SM
SERVICE PROGRAM MODE TABLE
.
to check that component.
No.
14
Transport Fan
15
Fusing Unit Fan -A224 only-
16
Not used
17
18
Upper Paper Feed Clutch
19
(Optional Paper Tray Unit)
Lower Paper Feed Clutch
20
(Optional Paper Tray Unit)
Upper Relay Clutch
21
(Optional Paper Tray Unit)
Lower Relay Clutch
22
(Optional Paper Tray Unit)
Main Motor
23
(Optional Paper Tray Unit)
Upper Paper Lift Motor (Up)
24
(Optional Paper Tray Unit)
Lower Paper Lift Motor (Up)
25
(Optional Paper Tray Unit)
Upper Paper Lift Motor (Down)
26
(Optional Paper Tray Unit)
13-53
A224M501.wmf