NCU PARAMETERS

3. NCU PARAMETERS
The following tables give the RAM addresses and units of calculation of the
parameters that the machine uses for ringing signal detection and automatic
dialing. The factory settings for each country are also given. Most of these
must be changed by RAM read/write (Function 06-1), but some can be
changed using NCU Parameter programming (Function 06-2); if Function
06-2 can be used, this will be indicated in the Remarks column. The RAM is
programmed in hex code unless (BCD) is included in the Unit column.
Address
480400
Country code for NCU parameters
480401
Line current detection time
480402
Line current wait time
480403
Line current drop detect time
SM
Function
4-54
Unit
Use the Hex value to program the country
code directly into this address, or use the
decimal value to program it using
Function 06-2 (parameter 00).
Country
Decimal
France
00
Germany
01
UK
02
Italy
03
Austria
04
Belgium
05
Denmark
06
Finland
07
Ireland
08
Norway
09
Sweden
10
Switzerland
11
Portugal
12
Holland
13
Spain
14
Israel
15
USA
17
Asia
18
Hong Kong
20
South Africa
21
Australia
22
New Zealand 23
Singapore
24
Malaysia
25
China
26
Taiwan
27
Turkey
32
Greece
33
20 ms
Line current is not detected if
480401 contains FF.
Remarks
Hex
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
11
12
14
15
16
17
18
19
1A
1B
20
21