G3 Switch 0B
FUNCTION
0 Protocol requirements:
Europe
0: Disabled 1: Enabled
1 Protocol requirements: Spain
0: Disabled 1: Enabled
2 Protocol requirements:
Germany
0: Disabled 1: Enabled
3 Protocol requirements:
France
0: Disabled 1: Enabled
4 PTT requirements: Germany
0: Disabled 1: Enabled
5 PTT requirements: France
0: Disabled 1: Enabled
6 Not used
7
G3 Switch 0C
FUNCTION
0
Pulse dialing method
Bit 1 Bit 0 Setting
1
0
0
Normal (P=N)
0
1
Oslo (P=10 - N)
1
0
Sweden (N+1)
1
1
Not used
2
Not used
to
7
G3 Switch 0D - Not used (do not change the settings)
G3 Switch 0E - Not used (do not change the settings)
G3 Switch 0F - Not used (do not change the settings)
(A639)
COMMENTS
The machine does not automatically reset these bits for
each country after a country code (System Switch 0F) is
programmed.
Change the required bits manually at installation.
Do not change the settings.
COMMENTS
P = Number of pulses sent out, N = Number dialed.
Do not change the settings.