15. SERVICE CALL CONDITIONS
15.1 SUMMARY
There are 3 levels of service call conditions.
Level
To prevent the machine from being damaged, the SC can only be
A
reset by a service representative (see the note below).
The copier cannot be operated at all.
The SC can be reset by turning the main switch off and on if the SC
B
was caused by a sensor error.
The copier can be operated as usual except for the unit related to
C
the service call.
NOTE: 1) If the problem concerns electrical circuit boards, first disconnect
then reconnect the connectors before replacing the PCBs.
2) If the problem concerns a motor lock, first check the mechanical
load before replacing motors or sensors.
3) To reset a Level A SC, enter SP 5-810 (SC code reset) and select
"1". Then hold down the Photo mode key and the
same time for at least 3 seconds (this does not require the main
switch to be turned off and on).
4) When a Level A or B SC occurs while in an SP mode, the display
will not indicate the SC number. If this occurs, check the SC
number after leaving the SP mode.
SM
SERVICE CALL CONDITIONS
Definition
13-63
key at the
A224