COPIER INSTALLATION

2.3 AUTO DOCUMENT FEEDER INSTALLATION

û
CAUTION
Unplug the copier power cord before starting the following procedure.
NOTE: When installing the DF, use the tool [A] in the accessory bag or a
screw driver.
1. Unpack the document feeder. Then, remove all tapes.
2. Remove the left scale [B] (2 screws).
3. Place the DF exposure glass [C] on the glass holder. The white mark [I]
must be at the rear side facing down.
4. Peel off the backing [D] of the double side tape attached to the rear side of
the scale guide [E], then adhere the scale guide (2 screws removed in step
2).
5. Attach the original size decal [F] to the scale guide.
NOTE: Place the decal at the rear edge, and the left side flush with the
scale paper guide [G], as shown.
6. Install the stud screws [H] for the DF on the copier.
(A193)
[A]
[B]
[E]
[D]
[C]
[G]
[F]
3-8
Rev. 6/13/97
[I]
[H]
SM