4.8 ORIGINAL LENGTH SENSOR REPLACEMENT

1. Remove the original table.
2. Remove the original guide [A] (3 screws).
3. Replace the following sensors.
Original Length Sensor 1 [B]
Original Length Sensor 2 [C]
SM
REPLACEMENT AND ADJUSTMENT
7-21
[A]
[B]
[C]
A623O023.wmf